Bloqueo infraclavicular continuo guiado por ultrasonido para cirugía de mano. Reporte técnico de la posición del brazo para la colocación del catéter perineural

Ultrasound-guided continuous infraclavicular block for hand surgery: Technical report on arm position for perineural catheter insertion

 

Fuente
Este artículo es originalmente publicado en:
De:
Cir Cir. 2015 Jan-Feb;83(1):15-22. doi: 10.1016/j.circir.2015.04.018.
Todos los derechos reservados para:
Copyright © 2015. Published by Masson Doyma México S.A.
Resumen
Antecedentes

La infusión perineural de anestésico local brinda mejor analgesia postoperatoria que la administración por vía intravenosa de opioides o antiinflamatorios en cirugía del miembro superior. Para colocar un catéter en el plexo braquial, el abordaje adecuado es el infraclavicular debido a que ofrece mayor estabilidad muscular. La abducción del brazo aparentemente coloca al plexo braquial más superficial, y que eleva en sentido cefálico la clavícula.

Objetivo

El objetivo de este trabajo es identificar si la abducción disminuye la distancia pielcordón y facilita el procedimiento de introducción del catéter por ultrasonido, asegurando una analgesia óptima. Esta posición del brazo y su relación con la colocación del catéter no se habían descrito anteriormente.

Material y métodos

Se incluyó a 58 pacientes adultos, sometidos a cirugía de antebrazo y mano, divididos en 2 grupos por colocación de la extremidad en abducción y aducción, se realizó un bloqueo infraclavicular mediante ecografía, colocando la punta del catéter adyacente al cordón posterior. En los pacientes del grupo en aducción con dificultad técnica elevada se permitió cambiar el brazo a abducción. Se registraron el número de punciones y de redirecciones, la facilidad de introducción del catéter y la distancia piel-plexo.

Resultados

La abducción del brazo desplazó cefálicamente la clavícula y la separó del transductor lineal, lo que permitió maniobrar la aguja en su angulación y redirección correcta, la distancia plexo a piel no disminuyó de manera significativa con la posición del brazo.

Conclusiones

La abducción del brazo permite un mejor rastreo en los bloqueos supraclaviculares guiados por ultrasonido y facilita la punción infraclavicular con la introducción del catéter.

Abstract
Background

Continuous perineural infusion of local anaesthetic provides better postoperative analgesia than intravenous administration of opioids or NSAIDs in upper limb surgery. The infraclavicular approach is a good option, due to the muscular stability to catheter; the abduction of the arm apparently makes the brachial plexus more superficial and which elevates the clavicle in the cephalic direction.

Aim

The aim of this study was to identify whether the abduction of the arm decreases the skin-plexus distance, making the perineural insertion of the catheter easier and for a better analgesia. This relationship between the arm and the insertion of catheter has not yet been established.

Material and methods

The study included 58 adult patients, undergoing forearm and hand surgery, initially divided into two groups, adduction and abduction. Ultrasound-guided infraclavicular block was performed, enabling the catheter tip to be positioned adjacent to the posterior cord. The group of patients with high technical difficulties were allowed to reposition the arm abduction. A record was made of the number of punctures, redirects, ease of insertion of the catheter, and skin-plexus distance.

Results

The abduction of the arm moved the clavicle towards the cephalad and separated it from the linear transducer, this allowed to manoeuvre the needle right angle and redirect it. The skin-plexus distance did not decrease significantly with arm position.

Conclusions

Arm abduction allows better scanning, facilitates the infraclavicular puncture, and catheter introduction.

Palabras clave
Bloqueo infraclavicular, Catéter, Ultrasonido, Cirugía de mano
Keywords
Catheter, Infraclavicular block, Ultrasound, Hand surgery
[PubMed – indexed for MEDLINE] 

Free full text

El uso de ultrasonido para prevenir la penetración de tornillos

Artículo en prensa

Articles in Press

Using Ultrasound to Prevent Screw Penetration

Fuente
Este artículo es originalmente publicado en:

http://www.ncbi.nlm.nih.gov/pubmed/26803568

http://www.jhandsurg.org/article/S0363-5023(15)01599-3/abstract
De:

Balfour GW1.

J Hand Surg Am. 2016 Jan 21. pii: S0363-5023(15)01599-3. doi: 10.1016/j.jhsa.2015.12.020. [Epub ahead of print] Todos los derechos reservados para:

Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

 

Abstract

Ultrasound is a readily available, inexpensive, easy-to-use, and rapid diagnostic tool. Physicians can use ultrasound to identify excessively long screws or screw penetration into joints. This article illustrates ultrasound identification of problem screws.

 

Resumen
El ultrasonido es una herramienta de diagnóstico fácilmente disponible, barato, fácil de usar y rápida. Los médicos pueden usar ultrasonido para identificar los tornillos excesivamente largos o penetración de tornillo en las articulaciones. Este artículo ilustra la identificación ecográfica de problemas con tornillos .

Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

KEYWORDS:

Ultrasound; distal radius; fractures; screw complications

PMID:26803568 [PubMed – as supplied by Publisher]